Home / Application Guide / Viscosity Setting

Conformal Coating Application Guide

Characteristics of each dispensing valve, a comparison of six resin chemistries, and quality checks and defect prevention on the shop floor.For product-specific conditions, follow the relevant TDS.

We finish viscosity control before shipping, not on your line

Conformal coating film quality depends heavily on viscosity at the moment of application. Wooseok Chemical sets a target viscosity (cP) for your resin and equipment, then adjusts, mixes, degasses and stabilizes the coating before it ships.

Problems caused by the wrong viscosity

Uneven film thickness

Too high a viscosity gives a thick film that flows unevenly; too low gives a thin film that leaves component edges and leads poorly covered.

Spray overspray & cobwebbing

When spray settings and viscosity don't match, droplets don't atomize evenly, making overspray and cobwebbing more likely.

Bubbles & pinholes

Air drawn in while mixing thinner and stirring on site stays behind as bubbles and pinholes after cure.

Thinning on site vs. viscosity pre-set before shipping

ItemThinning on sitePre-set by Wooseok Chemical
Viscosity adjustmentOperators measure out the thinning ratio and adjust on the lineAdjusted to the target viscosity before shipping
Mixing & degassingDone on site every time before usePacked in a stable state after uniform mixing and bubble removal
Lot-to-lot variationCan vary by operator and by daySet to the same target viscosity to reduce lot-to-lot variation
Line preparationTime for thinning, mixing and stabilizing needed every timeUse right after it reaches room temperature
Solvent handling on siteThinner has to be measured and mixedNo thinning work, so less solvent handling on site

Viscosity pre-setting process

  1. Photo · checking equipment and valves
    Step 1

    Review process conditions

    We check your application method and valve type, resin chemistry, application and whether you have curing equipment.

  2. Photo · viscometer measurement
    Step 2

    Set the viscosity spec

    We set the target viscosity (cP) and choose the dedicated thinner to match the resin and your dispensing equipment.

  3. Photo · mixing and degassing
    Step 3

    Adjust, mix & degas

    After adjusting to the target viscosity, we mix the coating thoroughly and remove bubbles to stabilize it.

  4. Photo · packing for shipment
    Step 4

    Ship & run on the line

    It is packed and shipped in a stable state. Once it reaches room temperature on arrival, load it straight into your equipment.

Viscosity settings differ by coating and equipment

Even within one chemistry, the right viscosity and setting method depend on the valve and working conditions. Tell us your resin and equipment, and we'll send a sample set to your conditions first.

We also supply coatings as supplied (standard specification), as well as dedicated thinners for each coating and thinners for cleaning nozzles and valves as separate items.

View thinners
Product photo coming soon

Viscosity is for the product as supplied (standard specification). Conformal coatings can also be shipped pre-set to the viscosity (cP) your equipment needs.